ASM1, ASM1E
Safety Monitor
 |
The AS-i Safety Monitor, the ASM1, is a core component of the AS-Interface Safety at Work system. Using configuration software it monitors the safety-related bus participants that are assigned to it, e.g. command devices, Multiple Light Beam Safety Devices and Safety Switches.
The Safety Monitor has an RS 232 diagnostics interface for the PC-supported configuration and diagnostics. Logical links can be easily created with the graphic user interface of the® based software. The user can combine safety sensors and command devices with a mouse click and assign different release circuits for switching off the dangerous movement. Depending on the device type, two dependent or independent release circuits with configurable contactor monitoring are available.
|
With an extended scope of functions, the ASM1E device type provides even more convenience with the configuration and diagnostics of a safety application monitored via an AS-Interface. Besides additional logic and diagnostics functions, ASM1E also has an activation/deactivation mode for parameterized software modules. The machine manufacturer can therefore already prepare the configuration of the Safety Monitor in the preliminary stage for all safety sensors that could be used with an extension.
The ASM1E-m variants are additionally equipped with an integrated muting function package to enable a continuous material flow, e.g. for automated production cells or packaging stations, while maintaining the protective function. The muting sensors required for this are easily integrated via standard AS-Interface input slaves; a separate muting controller is no longer required.
| Special features |
- Up to 31 safe AS-i slaves can be connected
- Freely selectable assignment (Drag & Drop) of the sensor to output-side release circuits with easy to operate asimon configuration and diagnostics software
- 48 link modules (e.g. OR, AND, FLIPFLOP) and turn on/off delays can be configured
- RS 232 interface for PC-supported system configuration, system diagnostics as well as configuration data transfer to replacement device
- Immediate switch-off STOP 0 and delayed switch-off STOP 1 of the release circuits can be parametered
- SERVICE button for teach-in with sensor swap-out
- 2-sensor parallel muting or 4-sensor sequential muting (ASM1E)
- Programmable muting logic (programmable with ASM1E-m/1 and ASM1E-m/2: muting time extension, muting timeout, muting sensor signal filter, close sequence, direction change, muting enable, muting override mode with buttons or key switches)
|
| Important technical data, overview |
| SIL in accordance with IEC 61508 and SILCL in accordance with IEC/EN 62061 |
3 |
| Performance Level (PL) in accordance with EN ISO 13849-1 |
e |
| Category in accordance with EN ISO 13849 |
4 |
| STOP category in accordance with IEC/EN 60204-1 |
0 and 1 |
| Supply voltage |
24 V DC, ±15 % |
| System response time |
Max. 40 ms |
| Protection rating |
IP 20 |
| Temperature range, operation |
-20...+60 °C |
| Dimensions (W x H x D) |
45 mm x 105 mm x 120 mm |
| Number of Safety Monitors per AS-Interface network |
4 (with maximum 31 integrated AS-i slaves) |
| Safety-related switching outputs (OSSDs) |
Up to 2 potential-free safety-related switching outputs
(1 A DC-13, 24 V DC / 3 A AC-15, 230 V AC) |
|