COMPACTplus-b Function Package blanking

Safety Light Curtains

Safety light curtains
CE TÜV cUL US listed IP 65

COMPACTplus Safety Light Curtains are Active Opto-electronic Protective Devices (AOPDs) of type 4 as defined by EN/IEC 61496-1 and (pr)EN/IEC 61496-2.

The aim of the COMPACTplus range is to live up to any future expectations in terms of top functionality, flexible integration and ease of operation. As an extension of the tried and tested COMPACT range, COMPACTplus incorporates as a bonus a number of additional fully integrated functions, such as for example a startup/restart interlock, electronic device monitoring and blanking. The various interface options that are available make it possible to connect the system at will either to conventional safety components or to safety bus systems.

So as to offer the best possible solution in every case for the specific tasks that are expected of them, the devices of the COMPACTplus range are available in different design variants, each with a different set of functions:

COMPACTplus-b
Safety Light Curtains with additional blanking functions (fixed and/or floating) plus reduced resolution of the protective field as well.

Advantages

  • Integrated functions such as
    • startup testing
    • restart interlock
    • device monitoring
    • Blanking

  • Additional connection available for contact-equipped safety sensor

  • Interface subassemblies:
    • semiconductor output
    • relay output
    • AS-i Safety
    • PROFIBUS DP
    • (other bussystems on demand)

  • Lokal socket or sensor connection module (optional)

  • Safety key for quick and easy parameterisation of protection zone blanking areas (Blanking)

  • SafetyLab“ configuration and diagnosis software for the PC

  • Insertable parameter module stores the device parameters so that components can easily be replaced

  • Infrared interface for PC-supported configuration and on-site diagnosis

  • Start-up/restart interlock, optionally by means of 2 start buttons

  • Static and dynamic relay monitoring

  • MultiScan, beam-related or scan-related multiple evaluation

  • Additional two-channel switch-off circuit

  • Fixed and floating blanking by safety key programming or key buttons

  • Freely determinable number and size of blanking zones

  • Reduced resolution also in partial areas of the protection zone

  • Position status signals for warning fields and the like