COMPACTplus-i Function Package initiation

Dimensional Drawings

COMPACTplus-i, Safety Light Curtains, basic design/host, with transistor outputs, relay outputs or AS-i bus connection
Dim.
A
[mm]
Dim.
B
[mm]
CPT/
CPR
[kg]
tH1 = Response time of the AOPD in ms with MultiScan factor H=1 (FS)
/T = Transistor outputs; /R = Relay outputs;
/A = AS-i bus connection; n = Number of beams
CP14-xxxx CP30-xxxx
n /T /R /A n /T /R /A
tH1 [ms] tH1 [ms] tH1 [ms] tH1 [ms] tH1 [ms] tH1 [ms]
150 284 0,7 16 5 20 10 8 5 20 10
225 359 0,9 24 7 22 12 12 7 22 12
300 434 1,1 32 9 24 14 16 5 20 10
450 584 1,5 48 12 27 17 24 7 22 12
600 734 1,9 64 15 30 20 32 9 24 14
750 884 2,3 80 18 33 23 40 10 25 15
900 1034 2,7 96 22 37 27 48 12 27 17
1050 1184 3,1 112 25 40 30 56 13 28 18
1200 1334 3,5 128 28 43 33 64 15 30 20
1350 1484 3,9 144 31 46 36 72 17 32 22
1500 1634 4,3 160 35 50 40 80 18 33 23
1650 1784 4,7 176 38 53 43 88 20 35 25
1800 1934 5,1 192 41 56 46 96 22 37 27
An increase of the MultiScan factor H using PC and SafetyLab extends the response time! The recalculation and adjusting of the safety distance is compulsory.
Dimensions series CP14, CP30 and CP50 basic design
Guest dimensions, weights and response times
Dim.
A
[mm]
Dim.
B
[mm]
Mass
CT-..S
CR-..S
[kg]
ts = Guest response time; n = Number of beams;
ts must be multiplied with the value of the configured MultiScan factor H
Example: C14-300S with H = 1 : ts = 6,4 ms
C14-300S with H = 2*) : ts = 12,8 ms
CP14-xxxxS CP30-xxxxS
n ts [ms]
H = 1
n ts [ms]
H = 1
150 284 0,7 16 3,2 8 1,6
225 359 0,9 24 4,8 12 2,4
300 434 1,1 32 6,4 16 3,2
450 584 1,5 48 9,6 24 4,8
600 734 1,9 64 12,8 32 6,4
750 884 2,3 80 16,0 40 8,0
900 1034 2,7 96 19,2 48 9,6
1050 1184 3,1 112 22,4 56 11,2
1200 1334 3,5 128 25,6 64 12,8
1350 1484 3,9 144 28,8 72 14,4
1500 1634 4,3 160 32,0 80 16,0
1650 1784 4,7 176 35,2 88 17,6
1800 1934 5,1 192 38,4 96 19,2
*) Can be set with SafetyLab, H = 2 corresponds to d-scan (double scan)

An increase of the MultiScan factor H using PC and SafetyLab extends the response time! The recalculation and adjusting of the safety distance is compulsory.

The total response time of the safety device tAOPD is calculated by adding the host response time to the guest response time.