COMPACTplus-m Function Package muting

Safety Light Curtains and Multiple Light Beam Safety Devices with integrated muting

Safety light curtains and multiple light beam safety devices with integrated muting
CE TÜV cUL US listed IP 65

COMPACTplus Safety Light Curtains and Multiple Light Beam Safety Devices are Active Opto-electronic Protective Devices (AOPDs) of type 4 as defined by EN/IEC 61496-1 and (pr)EN/IEC 61496-2.

The aim of the COMPACTplus range is to live up to any future expectations in terms of top functionality, flexible integration and ease of operation. As an extension of the tried and tested COMPACT range, COMPACTplus incorporates as a bonus a number of additional fully integrated functions, such as for example a startup/restart interlock, electronic device monitoring and blanking. The various interface options that are available make it possible to connect the system at will either to conventional safety components or to safety bus systems.

So as to offer the best possible solution in every case for the specific tasks that are expected of them, the devices of the COMPACTplus range are available in different design variants, each with a different set of functions:

COMPACTplus-m
Safety Light Curtains, Multiple Light Beam Safety Devices and Transceivers with the “Muting” function package for bridging the safety device for a limited period, with, for example, proper material transport through the protective field.

Advantages

  • Integrated functions such as
    • startup testing
    • restart interlock
    • device monitoring
    • Muting
    • Muting-Override
  • Additional connection available for contact-equipped safety sensor

  • Muting design variant as transceiver with direct connection to as many as 4 muting sensors and muting lamps based on M12 connection technology

  • >Interface subassemblies:
    • semiconductor output
    • relay output
    • AS-i Safety
    • PROFIBUS DP
    • (other bussystems on demand)

  • Lokal socket or sensor connection module (optional)

  • Integrated, monitored override function in accordance with the most recent safety requirements for the safe release of material after switching off

  • „SafetyLab“ configuration and diagnosis software for the PC

  • Insertable parameter module stores the device parameters so that components can easily be replaced

  • Infrared interface for PC-supported configuration and on-site diagnosis

  • Start-up/restart interlock, optionally by means of 2 start buttons

  • Static and dynamic relay monitoring

  • MultiScan, beam-related or scan-related multiple evaluation

  • Additional two-channel switch-off circuit

  • 2-, 3- or 4-sensor muting

  • Transmitter/receiver or transceiver/reflection mirror principle

  • Additional control signals for muting and muting timer