| General system data |
| Type in accordance with IEC/EN 61496 |
2 |
| Service life (TM) in accordance with EN ISO 13849-1 |
20 years |
| Category in accordance with EN ISO 13849 |
2 |
| Mean time to dangerous failure (MTTFd) in accordance with EN ISO 13849-1 |
414,1 years |
| Operating range |
0...10 m |
| Response time |
0.5 ms |
| Operating voltage UB |
10... 30 V DC |
| Safety class |
II |
| Protection rating |
IP 67 |
| Temperature range, operation / storage |
-25...+65 °C / -40...+70 °C |
| Dimensions |
Cylindrical construction, M18x1 |
| Housing |
metal, plastic |
| Weight (transmitter and receiver) |
15 g (plug variant, plastic housing), 85 g (cable variant, plastic housing), 35 g (plug variant, metal housing), 105 g (cable variant, metal housing) |
| Transmitter |
| Current consumption |
25 mA |
| Transmitter diodes, class in accordance with EN 60825 |
1 |
| Light source |
Red light |
| Wavelength |
660 nm |
| Activation input for testing and series connection |
active ≥ 8 V / not active ≤ 1.5 V |
| Connection system |
Cable, 2 m, M12 round pin plug, 4-pin |
| Receiver |
| Current consumption |
25 mA without external load |
| Switching output |
pnp transistor output |
| Switching voltage high active |
Min. Uv – 1.6 V |
| Switching voltage low |
max. 1.6 V |
| Output current |
max. 100 mA |
| Connection system |
Cable, 2 m, M12 round pin plug, 4-pin |