| General system data |
| Type in accordance with IEC/EN 61496 |
4 |
| Performance Level (PL) in accordance with EN ISO 13849-1 |
e |
| Probability of a failure to danger per hour (PFHd) in accordance with the average number of annual nop activations (for the calculation formula, see EN ISO 13849-1:2008, chapter C.4.2 and C.4.3) |
nop = 4.800 |
3,4 x 10-8 1/h |
| nop = 28.800 |
4,9 x 10-8 1/h |
| nop = 86.400 |
9,9 x 10-8 1/h |
| Service life (TM) in accordance with EN ISO 13849-1 |
20 years |
| Number of cycles until 10 % of the components have a failure to danger (B10d) |
With DC1 (ohmic load) |
400.000 |
| With AC1 (ohmic load) |
400.000 |
| With DC13 (inductive load) |
400.000 |
| With AC15 (inductive load) |
400.000 |
| Low load (20% nominal load) |
20.000.000 |
| Category in accordance with EN ISO 13849 and EN 954-1 |
4 |
| Operating range |
0...60 m |
| Response time |
20 ms |
| Operating voltage UB |
24 V DC ± 15 % |
| Connection cable length |
max. 100 m at 0.25 mm 2 |
| Safety class |
I |
| Protection rating |
IP 65 |
| Temperature range, operation |
-25...+60 °C |
| Temperature range, storage |
-25...+70 °C |
| Relative humidity |
95 % |
| Dimensions (WxHxD) |
38 mm x 127 mm x 99 mm |
| Housing |
Aluminum diecast |
| Weight |
580 g (transmitter), 600 g (receiver) |
| Transmitter |
| Transmitter diodes, class in accordance with EN 60825 |
1 |
| Light source |
Infrared light |
| Wavelength |
880 nm |
| Current consumption |
100 mA |
| Connection system |
Cable gland (PG11)
Spring terminals
Plug connection, DIN 43651 |
| Receiver |
| Current consumption |
250 mA |
| Safety-related switching outputs (OSSDs) |
2 relay outputs (NO) |
| Switching current |
Max. 2 A, AC-1/DC-1 |
| Switching voltage |
Max. 250 V AC |
| Connection system |
Cable gland (PG11)
Spring terminals
Switching connection, DIN 43651 |