| General system data |
| Type in accordance with IEC/EN 61496 |
2 |
| Service life (TM) in accordance with EN ISO 13849-1 |
20 years |
| Category in accordance with EN ISO 13849 and EN 954-1 |
2 |
| Mean time to dangerous failure (MTTFd) in accordance with EN ISO 13849-1 |
445,2 years |
| Operating range |
0...50 m (infrared light)
0...30 m (red light) |
| Response time |
1 ms |
| Operating voltage UB |
10... 30 V DC (incl. residual ripple) |
| Safety class |
II |
| Protection rating |
IP 67 |
| Temperature range, operation |
-20...+60 °C |
| Temperature range, storage |
-40...+70 °C |
| Dimensions (WxHxD) |
30 mm x 90 mm x 70 mm |
| Housing |
metal
plastic |
| Weight (transmitter and receiver) |
380 g (metal housing)
260 g (plastic housing) |
| Transmitter |
| Current consumption |
50 mA |
| Transmitter diodes, class in accordance with EN 60825 |
1 |
| Light source |
Infrared light
red light |
| Wavelength |
880 nm (infrared light) 660 nm (red light) |
| Activation input for testing and series connection |
24 V DC active ≥ 8 V inactive ≤ 2 V |
| Connection system |
Cable gland
M12 round pin plug, 4-pin |
| Receiver |
| Current consumption |
50 mA without external load |
| Switching output |
pnp transistor output |
| Switching voltage high active |
Min. Uv – 2 V |
| Switching voltage low |
max. 2 V |
| Output current |
max. 100 mA |
| Connection system |
Cable gland
M12 round pin plug, 4-pin |