| General system data |
| Type in accordance with IEC/EN 61496 |
Type 2 in combination with a Safety Interface or a Test Monitoring Unit |
| Service life (TM) in accordance with EN ISO 13849-1 |
20 years |
| Category in accordance with EN ISO 13849 and EN 954-1 |
2 |
| Mean time to dangerous failure (MTTFd) in accordance with EN ISO 13849-1 |
On request |
| Operating range |
0...10 m |
| Response time |
2 ms |
| Operating voltage UB |
10... 30 V DC (incl. residual ripple) |
| Safety class |
II |
| Protection rating |
IP 67 |
| Temperature range, operation |
-20...+60 °C |
| Temperature range, storage |
-40...+70 °C |
| Housing |
Metal |
| Weight (transmitter and receiver) |
70 g |
| Transmitter |
| Current consumption |
35 mA |
| Transmitter diodes, class in accordance with EN 60825 |
1 |
| Light source |
Red light |
| Wavelength |
660 nm |
| Activation input for testing and series connection |
24 V DC active ≥ 8 V inactive ≤ 2 V |
| Connection system |
M12 round pin plug, 5-pin |
| Receiver |
| Current consumption |
35 mA without external load |
| Switching outputs |
2 push-pull switching outputs
Pin 2: pnp dark switching, npn light switching
Pin 4: pnp light switching, npn dark switching |
| Switching voltage high active |
Min. Uv – 2 V |
| Switching voltage low |
max. 2 V |
| Output current |
max. 100 mA |
| Connection system |
M12 round pin plug, 5-pin |