MSI-i, MSI-ix

Modular Safety Interfaces, Category 4

Modular Safety Interfaces, Category 4
CE BG

The modular safety interface MSI-i serves as a control module for cyclical control and rear area monitoring at mechanical and hydraulic presses.

In addition, the version MSI-ix allows the connection of a second optoelectronic protective device or an Emergency Stop command device or safety switch.

Advantages

  • Safety interface, Type 4, in accordance with EN/IEC 61496-1 or EN 954-1, Cat. 4

  • 30 s time monitoring during cyclical operation

  • 2 normally open contacts, 6 A max., or 2 failsafe pnp outputs, 0.5 A

  • RS 232 interface for PC-supported diagnostics and easy start-up

  • Status outputs "relay status" and "start/restart interlock locked"

  • Plug-in connection terminals and plug-in output subassemblies

  • Counting of relay operations with pre-failure message for preventive maintenance

  • Warning output “relay life expectancy reached, recommend relay replacement"

  • Housing width: 35 mm