COMPACTplus/AS-i
Multiple Light Beam Safety Devices
 |
| Special features |
- Type 4 Multiple Light Beam Safety Device in accordance with IEC/EN 61496-1/-2
- Integrated AS-Interface, bus connection via the M12-AS-i Adapter for AS-i data transfer and separate 24 Volt power supply
- Safe data transfer of the OSSD signals via AS-Interface
- Device swap-out without PC via SERVICE function of the AS-i Safety Monitor
- Direct connection of muting sensors, start/restart button or indicator directly on the device via sensor connection module
- Muting restart function possible via AS-Interface by calling up AS-i-IC parameters
- Additional diagnostics information via AS-Interface, e.g. muting sensors status, muting or weak signal display
|
|
| Important technical data, overview |
| Type in accordance with IEC/EN 61496 |
4 |
| SIL in accordance with IEC 61508 and SILCL in accordance with IEC/EN 62061 |
3 |
| Performance Level (PL) in accordance with EN ISO 13849-1 |
e |
| Category in accordance with EN ISO 13849 |
4 |
| Number of beams |
2 |
3 |
4 |
| Beam distance |
500 mm |
400 mm |
300 mm |
| Range (type-dependent) |
Cxx0/y:
Cxx1/y: |
0...18 m
6...70 m |
| Muting transceiver range (type-dependent) |
0...6.5 m |
| Profile cross-section |
52 mm x 55 mm |
| Safety-related switching output (OSSD) |
AS-i Safety Interface |
| Connection system |
M12 plug (AS-i Safety) |
| AS-i profile |
S-7.B.1, safe slave |
| Slave address |
1...31, programmable (factory setting = 0) |
| Cycle time in accordance with AS-i specifications |
5 ms |
| Current consumption from AS-i circuit |
50 mA |
| Sensor response time |
24 ms, 25 ms (muting transceiver) |
| Restart delay time |
20...5000 ms, can be set with SafetyLab software,
presetting 100 ms (after protective field release) |
|
|
|