General system data
|
| Type in accordance with IEC/EN 61496 |
4 |
| SIL in accordance with IEC 61508 and SILCL in accordance with IEC/EN 62061 |
3 |
| Performance Level (PL) in accordance with EN ISO 13849-1 |
e |
| Probability of a failure to danger per hour (PFHd) |
up to 4 beams |
1.90 x 10 -8 1/h |
| Service life (TM ) in accordance with EN ISO 13849-1 |
20 years |
| Number of cycles until 10 % of the components have a failure to danger(B10d)* |
With DC1 (ohmic load) |
On request |
| With AC1 (ohmic load) |
On request |
| With DC13 (inductive load) |
630,000 (5 A, 24 V) |
| With AC15 (inductive load) |
1,480,000 (3 A, 230 V) |
Low load
(20% nominal load) |
On request |
| Category in accordance with EN ISO 13849 |
4 |
| Number of beams |
2 (Muting Transceiver) |
2 (transmitter/receiver) |
3 (transmitter/receiver) |
4 (transmitter/receiver) |
| Beam distance |
500 mm |
500 mm |
400 mm |
300 mm |
| Range (type-dependent) |
CPxx0/y: 0...18 m
CPxx1/y: 6...70 m |
| Muting Transceiver range |
0...6.5 m |
| Response time |
Transistor output |
20 ms |
19 ms |
19 ms |
19 ms |
| Relay output |
35 ms |
34 ms |
34 ms |
34 ms |
| AS-i Safety Interface |
25 ms |
24 ms |
24 ms |
24 ms |
| PROFIsafe interface |
40 ms |
39 ms |
39 ms |
39 ms |
| Beam height above reference plane in accordance with EN 999 |
400, 900 mm |
400, 900 mm |
300, 700, 1100 mm |
300, 600, 900, 1200 mm |
| Supply voltage |
24 V DC, ±20 % |
| Connection cable length |
max. 100 m with 1.0 mm² |
| Safety class |
III and I (depending on model) |
| Protection rating |
IP 65** |
| Temperature range, operation |
0...+50 °C |
| Temperature range, storage |
-25...+70 °C |
| Relative humidity |
15...95 % |
| Profile cross-section |
52 mm x 55 mm |
| Weight per device (length-dependent) |
1.90...3.10 kg |
|
Transmitter
|
| Transmitter diodes, class in accordance with EN 60825 |
1 |
| Wavelength |
880 nm |
| Current consumption |
75 mA |
| Connection system |
Cable gland (M20)
Hirschmann plug (DIN 43651),
12-pin MIN-style plug (MIN series),
3-pin M12 plug, 5-pin |
| External test input |
24 V DC, max. 20 mA |
|
Receiver
|
| Current consumption |
160 mA without external load, Muting sensors and Muting indicator |
| Safety-related switching outputs (OSSDs) |
2 PNP transistor outputs
(short-circuit proof, cross circuit monitored)
2 relay outputs (normal open contacts)
AS-i Safety interface
PROFIsafe interface |
| Switching voltage high active |
Min. Uv -1.0 V |
| Switching voltage low |
Max. +2.5 V |
| Switching current |
Typical, 500 mA |
| Connection system |
Cable gland (T1: M20, R1: M25)
Hirschmann plug (DIN 43651),
T2: 12-pin, R2: 12-pin
MIN-style plug (MIN series),
T3: 7-pin, R3: 12-pin
M12 plug (safety bus systems),
5-pin, T4: 8-pin |
|
Transceiver (2-beam)
|
| Current consumption |
160 mA without external load, Muting sensors and Muting indicator |
| Safety-related switching outputs (OSSDs) |
2 PNP transistor outputs
(short-circuit proof, cross circuit monitored)
2 relay outputs (normal open contacts)
AS-i Safety interface
PROFIsafe interface |
| Switching voltage high active |
Min. Uv -1.0 V |
| Switching voltage low |
Max. +2.5 V |
| Switching current |
Typical, 500 mA |
| Connection system |
Cable gland (T1: M20, R1: M25)
Hirschmann plug (DIN 43651),
T2: 12-pin, R2: 12-pin
MIN-style plug (MIN series),
T3: 7-pin, R3: 12-pin
M12 plug (safety bus systems),
5-pin, T4: 8-pin |