COMPACTplus/PROFIsafe
Dimensional Drawings
|
|
|
|
While the dimensions and weights correspond with those in the connecting and operating instructions for the device, the factory setting of the response time of the receiver is 20 ms (response time of the PROFIsafe Interface) greater than that of the corresponding device with transistor output. The response time of the protective field required for calculating the response time of the projected safety circuit is shown separately in the following tables in the column t_PFHx.
Safety Light Curtains, response times:
|
|
Protective
field height
[mm] |
t_H1 = Response time of the AOPD in ms, MultiScan factor H=1 (FS) |
| t_PFH1 = Response time of the protective field in ms at H=1 (FS) |
Resolution
14 mm |
Resolution
30 mm |
Resolution
50 mm |
Resolution
90 mm |
| t_H1 |
tPF_H1 |
t_H1 |
t_PFH1 |
t_H1 |
t_PFH1 |
t_H1 |
t_PFH1 |
| 150 |
25 |
5 |
25 |
5 |
|
|
|
|
| 225 |
27 |
7 |
27 |
7 |
|
|
|
|
| 300 |
29 |
9 |
25 |
5 |
|
|
|
|
| 450 |
32 |
12 |
27 |
7 |
27 |
7 |
|
|
| 600 |
35 |
15 |
29 |
9 |
25 |
5 |
|
|
| 750 |
38 |
18 |
30 |
10 |
26 |
6 |
26 |
6 |
| 900 |
42 |
22 |
32 |
12 |
27 |
7 |
27 |
7 |
| 1050 |
45 |
25 |
33 |
13 |
28 |
8 |
25 |
5 |
| 1200 |
48 |
28 |
35 |
15 |
29 |
9 |
25 |
5 |
| 1350 |
51 |
31 |
37 |
17 |
29 |
9 |
26 |
6 |
| 1500 |
55 |
35 |
38 |
18 |
30 |
10 |
26 |
6 |
| 1650 |
58 |
38 |
40 |
20 |
31 |
11 |
27 |
7 |
| 1800 |
61 |
41 |
42 |
22 |
32 |
12 |
27 |
7 |
| 2100 |
|
|
45 |
25 |
33 |
13 |
28 |
8 |
| 2400 |
|
|
48 |
28 |
35 |
15 |
29 |
9 |
| 2700 |
|
|
51 |
31 |
37 |
17 |
29 |
9 |
| 3000 |
|
|
55 |
35 |
38 |
18 |
30 |
10 |
|
|
Multiple light beam safety devices, response times:
|
|
Beam
distance
[mm] |
t_H7 = Response time of the AOPD in ms, MultiScan factor H=7 (FS) |
| t_PFH7 = Response time of the protective field in ms at H=7 (FS) |
| Number of beams = 2 |
Number of beams = 3 |
Number of beams = 4 |
| t_H7 |
_PFH7 |
t_H7 |
_PFH7 |
t_H7 |
_PFH7 |
| 500 |
39 |
19 |
|
|
|
|
| 400 |
|
|
39 |
19 |
|
|
| 300 |
|
|
|
|
39 |
19 |
|
|
Muting transceiver, response times:
|
|
Beam
distance
[mm] |
t_H8 = Response time of the AOPD in ms, MultiScan factor H=8 (FS) |
| t_PFH8 = Response time of the protective field in ms at H=8 (FS) |
| Number of beams = 2 |
| t_H8 |
t_PFH8 |
| 600 |
40 |
20 |
| 500 |
40 |
20 |
|
|
|
|
|
|