COMPACTplus/PROFIsafe

Dimensional Drawings

While the dimensions and weights correspond with those in the connecting and operating instructions for the device, the factory setting of the response time of the receiver is 20 ms (response time of the PROFIsafe Interface) greater than that of the corresponding device with transistor output. The response time of the protective field required for calculating the response time of the projected safety circuit is shown separately in the following tables in the column t_PFHx.

Safety Light Curtains, response times:

Protective
field height
[mm]
t_H1 = Response time of the AOPD in ms, MultiScan factor H=1 (FS)
t_PFH1 = Response time of the protective field in ms at H=1 (FS)
Resolution
14 mm
Resolution
30 mm
Resolution
50 mm
Resolution
90 mm
t_H1 tPF_H1 t_H1 t_PFH1 t_H1 t_PFH1 t_H1 t_PFH1
150 25 5 25 5        
225 27 7 27 7        
300 29 9 25 5        
450 32 12 27 7 27 7    
600 35 15 29 9 25 5    
750 38 18 30 10 26 6 26 6
900 42 22 32 12 27 7 27 7
1050 45 25 33 13 28 8 25 5
1200 48 28 35 15 29 9 25 5
1350 51 31 37 17 29 9 26 6
1500 55 35 38 18 30 10 26 6
1650 58 38 40 20 31 11 27 7
1800 61 41 42 22 32 12 27 7
2100     45 25 33 13 28 8
2400     48 28 35 15 29 9
2700     51 31 37 17 29 9
3000     55 35 38 18 30 10

Multiple light beam safety devices, response times:

Beam
distance
[mm]
t_H7 = Response time of the AOPD in ms, MultiScan factor H=7 (FS)
t_PFH7 = Response time of the protective field in ms at H=7 (FS)
Number of beams = 2 Number of beams = 3 Number of beams = 4
t_H7 _PFH7 t_H7 _PFH7 t_H7 _PFH7
500 39 19        
400     39 19    
300         39 19

Muting transceiver, response times:

Beam
distance
[mm]
t_H8 = Response time of the AOPD in ms, MultiScan factor H=8 (FS)
t_PFH8 = Response time of the protective field in ms at H=8 (FS)
Number of beams = 2
t_H8 t_PFH8
600 40 20
500 40 20