ROBUST RR/RT 23

Technical Data

General data
Multiple Light Beam Safety Device
ROBUST RR/RT 23
Safety category
Type 2 according to EN-/IEC 61496-1,-2
max. Range (per single beam) 50 m
Light source LED, Infrared (alternating light)
Distance between beams (3 beams) 400 mm
Response time (from interruption of the sensing field to the switching off of the OSSD) 8 ms
Enclosure rating IP 67
Ambient temperature -25 °C bis +55 °C
Supply voltage 24 V DC ±15 %
Residual ripple 10 %
Current consumption
Transmitter 150 mA
Receiver 130 mA
Wave lenght 880 nm
Optical parts Glass Ø 30 mm
Effective apperture angel ab 3 m ±4°
Switching frequency sensor 200 Hz
Test activation TA Transmitter activ 3 mA
Transmitter Transmitter not activ 1 mA
Input resistance 5 k
Response time 400
Lens heating system Integrated
Switching output (OSSD*) 1 pnp-transistor-output, bright switching
Output load max. 200 mA
Transmitter activation (test input) highly-activ, Ri 5 k
Connection M12 Randplug-in connection
4 (5) polig, B-codiert
Assembly position As desired
Mounting with M6 sliding brackets, adjustable
Weight Transmitter 2100 g,
Receiver 2200 g
Storage temperature -30 °C bis +70 °C
Housing Aluminium-extrusion profile
Color/varnishing Yellow, RAL 1021 (lead- and cadmium free)
Housing/isolation class Protection class 3, operation only with safe low voltage DIN VDE 0100 part 410
Display Receiver
LED red
LED green blinking
LED green

Light path interrupted
Light path free, no functional reserve
Light path free, with functional reserve
Display Transmitter
LED yellow
Transmitter activated
VDE Protection class III, to be operated only with safe protective low voltage according to DIN VDE 0100, Part 410
* Protection switches
1 : transient protection
2 : pole reversal protection
3 : Short circuit protection