ROBUST 42/43/44
Technical Data
|
|
|
| General Data |
|
|
Multiple Light Beam Safety Device
|
ROBUST
|
|
Safety category
|
Type 4 according to EN-/IEC 61496-1, -2
(self-monitoring)
|
| Response time (from interruption of the sensing field to the switching off of the OSSDs) |
20 ms |
| Enclosure rating |
IP 67 |
| Ambient temperature |
-25 °C bis + 55 °C |
| Storage temperature |
-30 °C bis +70 °C |
| Supply voltage |
24 V DC ±15 % |
| Residual ripple |
10 % |
| Wave lenght |
880 nm |
| Output signal switching devices (OSSDs) |
Relay, 2 S, positive guided |
| Safety fuse |
External with max. 4 Amp (medium response) |
Overvoltage classification according to
DIN VDE 0110T1 |
2 for voltage 300 V AC
4 for voltage 50 V AC |
| Max. switching voltage |
250 V AC |
| Max. switching current |
Per contact 4 A, AC-1 |
| Connection |
with screw terminals, max. 2,5 mm2 |
| Max. switching current |
PG 11 screwing with tension relief |
| Optical parts |
Glass Ø 30 mm |
| Effective apperture angel |
From 3 m ± 2° |
| Lens heating system |
Integrated |
| Housing material |
Aluminium-extrusion profile |
| Color/housing paint |
Yellow, RAL 1021 (lead- and cadmium free) |
| Housing/isolation class |
Protection class 1 |
| Assembly position |
Optional |
| Mounting |
with M6 sliding brackets, adjustable |
|
|
| Transceiver RRT 42 |
|
|
| Operating range 1) |
0,5 - 2,5 m with PM 2
1,5 - 8 m with PM 2V
0,5 - 50 m with AMI 42 |
| Beam distance (2 light beams) |
500 mm |
| Current consumption |
280 mA |
| Weight |
900 g |
|
|
| 1) Operating range: recommended Range with functional reserve |
|
|
| Transmitter RT 43/Receiver RR 43 |
|
| Max. Range |
50 m |
| Current consumption |
RT 43: 200 mA, RR 43: 300 mA |
| Beam distance (3 light beams) |
400 mm |
| Weight |
RT 43: 2100 g, RR 43: 2200 g |
|
|
| Transceiver RRT 44 |
|
|
| Operating range |
0,5 - 2,5 m with PM 4 - 300
1,5 - 8 m with PM 4 - 300 (V)
0,5 - 50 m with AMI 42 |
| Beam distance (4 light beams) |
300 mm |
| Current consumption |
350 mA |
| Weight |
1800 g |
|
|
| 1) Operating range: recommended Range with functional reserve |
|
|
|
|
|
|
|