ROBUST RRT 42.3 MCB-2.1
Electrical Connection
|
|
| To connect the device, the connection terminal should be released from the holding rings and drawn out of the profile far enough to make it possible for the terminals to be connected. After connecting the terminal, push it back into the profile and screw it firmly in place (important earth contact). |
|
 |
|
|
 |
As an operating or switching voltage, e.g. for relay outputs, only 24 V DC is permissible.
The cable to the switching cabinet must be laid in such a way that it is protected from mechanical damage.
|
|
Examples of connections using MSI-m (mx)/R(Rx) may be requested from the Leuze lumiflex hotline on 0049 (0)8141/5350-121.
Note: Instead of the bridge at connection point 2: input 12 (power supply to the muting sensors) may also be used for the activation of the muting process e.g. by the drive of the transport belt. In this case, when activating a voltage of + 24 V DC should be applied to input 12.
|
|
|
|
|
|
|
|