SLS 46

Technical Data

Optical data
Typ. operating range limit 1) 0 …36m
Operating range 2) 0 …30m
Light source LED (modulated light)
Wavelength 880nm
Timing
Switching frequency 200Hz
Response time 2,5ms
Delay before start-up 100ms
Electrical data
Operating voltage UB 10 … 30VDC (incl. residual ripple)
Residual ripple 15% of UB
Bias current 30mA
Switching output PNP transistor
Function characteristics light/dark switching (complementary)
Signal voltage high/low (UB -2V)/ 2V
Output current max. 100mA
Indicators
Receiver
LED green
LED yellow
LED yellow flashing

ready
light path free
light path free, no performance reserve
Transmitter
LED green
LED yellow

ready
transmitter active
Mechanical data
Housing plastic
Optics cover plastic
Weight 100g
Connection type M12 connector, or
cable, cable length: 2000mm, PVC
Environmental data
Ambient temp. (operation/storage) -20°C … +60°C/-40°C … +70°C
Protective circuit 3) 2, 3
VDE safety class 4) II, all-insulated
Protection class IP65
Standards applied IEC 60947-5-2
Options
Activation input activ
Transmitter active/not active 8V/ 2V
Activation/disable delay 1ms/ 2ms
Input resistance 10k ±10%
1) Operating range limit: max. attainable range without performance reserve
2) Operating range: recommended range with performance reserve
3) 2=polarity reversal protection, 3=short-circuit protection for all outputs
4) Rating voltage 250VAC

Remarks:
The protective throughbeam photoelectric sensor is a contactless active protective device only in connection with a safety-relevant control system, in which the cyclical testing of transmitter and receiver is carried out according to EN 61496-1, category 2 (testing). Minimum blackening object: Ø22mm.

At the device, the tip of the marker indicates the location of the optical axis.