SLS 46
Technical Data
|
|
| Optical data |
| Typ. operating range limit 1) |
0 …36m |
| Operating range 2) |
0 …30m |
| Light source |
LED (modulated light) |
| Wavelength |
880nm |
| Timing |
| Switching frequency |
200Hz |
| Response time |
2,5ms |
| Delay before start-up |
100ms |
| Electrical data |
| Operating voltage UB |
10 … 30VDC (incl. residual ripple) |
| Residual ripple |
15% of UB |
| Bias current |
30mA |
| Switching output |
PNP transistor |
| Function characteristics |
light/dark switching (complementary) |
| Signal voltage high/low |
(UB -2V)/ 2V |
| Output current |
max. 100mA |
| Indicators |
Receiver
LED green
LED yellow
LED yellow flashing |
ready
light path free
light path free, no performance reserve |
Transmitter
LED green
LED yellow |
ready
transmitter active |
| Mechanical data |
| Housing |
plastic |
| Optics cover |
plastic |
| Weight |
100g |
| Connection type |
M12 connector, or
cable, cable length: 2000mm, PVC |
| Environmental data |
| Ambient temp. (operation/storage) |
-20°C … +60°C/-40°C … +70°C |
| Protective circuit 3) |
2, 3 |
| VDE safety class 4) |
II, all-insulated |
| Protection class |
IP65 |
| Standards applied |
IEC 60947-5-2 |
| Options |
| Activation input activ |
|
| Transmitter active/not active |
8V/ 2V |
| Activation/disable delay |
1ms/ 2ms |
| Input resistance |
10k ±10% |
|
|
1) Operating range limit: max. attainable range without performance reserve
2) Operating range: recommended range with performance reserve
3) 2=polarity reversal protection, 3=short-circuit protection for all outputs
4) Rating voltage 250VAC
|
|
|
Remarks:
The protective throughbeam photoelectric sensor is a contactless active protective device only in connection with a safety-relevant control system, in which the cyclical testing of transmitter and receiver is carried out according to EN 61496-1, category 2 (testing). Minimum blackening object: Ø22mm.
At the device, the tip of the marker indicates the location of the optical axis.
|
|
|
|
|
|