SLS 78M/P-1730-T2-4

Technical Data

Safety Light Barrier
SLS 78M/P-1730-T2-4
Safety category Type 2 according to EN 61496-1,-2 in combination with a test monitoring unit.
Operating range 1) 0 - 120 m
Limit range 2) 0 - 150 m
Light source LED (alternating light)
Wave lenght 880 nm
Enclosure rating IP 65
Operation voltage UB 24 V DC 20 %
Residual ripple 15 % von UB
No-load current Transmitter: 60 mA
Receiver: & 35 mA
Switching output pnp transistor output
Releasing time max. 200 mA
Function bright switching
Signal voltage high/low (UB - 2 V) / 2 V
Output current max. 200 mA
Switching frequency 300 Hz
Pickup time 1,7 ms
Readiness delay 5 ms
Initial impulse min. 1,7 ms
Transmitter
LED yellow

Transmitter ON
Receiver
LED green
LED green, flashing
LED red

Light path free
Light path free, no functional reserve
Light path interrupted
Housing Aluminium die casting
Optical parts Glass, Effective apperture angel ±4°
Weight 463 g
Connection M12 circular plug connection, 4-pin plug
Ambient temperature (operation/storage) -25 °C ... +60 °C / -30 °C ... +70 °C
VDE-Protection class III
Protective cabling 3) 1, 2, 3
Shock proof Semi sine, 30 gn, 11 ms (IEC 947-5-2)
Vibration proof 10 - 55 Hz, max. 7,5 gn (IEC 947-5-2)
Electromagnetic tolerance Degree of severity 3 (IEC 801.2...4)
Transmitter activ/not aktiv 8 V / 2 V or not wired
Activation/locking delay 400
Input resistance 4,7 k ± 10 %
1) Operating range: recommended Range with functional reserve
2) Limit range: max. possible range without function reserve
3) 1 = transient protection, 2 = pole reversal protection, 3 = Short circuit protection

Activating input enables a logical connection of several light barriers.

Example:

Connection of several light barriers (max. 6 per channel) in series-connection to a monitoring unit.

Function:

The active input on the first light barrier transmitter of a series connection is connected to the initial input of the monitoring unit. After monitoring is released, transmitter is activated. The matching first receiver switches to signal "high". With this signal the next transmitter is activated and the matching receiver switches also to signal "high". The last receiver switching output of the group series connection is led back to the monitoring unit. The operating voltage is connected separately to all sensors.

Note:

The through-beam safety light barrier is an electro-sensitive protective device only in connection with a safety-relevant control system where the cyclical testing of transmitter and receiver is carried out according to EN-/IEC 61496-1, 2, category 2 (testing). The power supply to the light barrier must intercept changes and interruptions in the supply voltage in accordance with EN 61496-1. Minimum darkening object Ø 30 mm.