LS 92/4.8
Technical Data
|
|
|
Safety Light Barrier
|
LS 92/4.8
|
| Safety category |
Type 2 according to EN-/IEC 61496-1,-2 in combination with a test monitoring unit. |
| Operating range 1) |
0 - 12 m |
| Limit range 2) |
0 - 15,6 m |
| Response time |
2,5 ms |
| Stand-by delay |
100 ms |
| Enclosure rating |
IP 67, IP 65 for all S-types |
| Shock proof |
Semi sine, 30 gn, 11 ms (IEC 947-5-2) |
| Vibration proof |
10 - 55 Hz, max. 7,5 gn (IEC 947-5-2) |
| Electronic compatibility |
prEN 50100-1 |
| Ambient temperature (operation/storage) 3) |
-20 °C ... +60 °C / -30 °C ... +70 °C |
| External light limit |
30 kLux (IEC 947-5-2) |
| VDE-Protection class |
I for S-types and cable version |
| VDE-Protection class 4) |
II for L-types (M 12 circ. plug-in connection) |
| Protective cabling 5) |
2, 3 |
| Operation voltage UB |
10... 30 V DC (residual ripple included) |
| Residual ripple |
15 % von UB |
| No-load current |
35 mA |
| Switching output 3) |
pnp transistor output |
| Output current |
max. 100 mA |
| Function |
bright/dark switching
(by pole reversal of UB) |
| Signal voltage high/low |
(UB - 2 V) / 2 V |
| Connection |
M12 circular plug-in connection - LS 92/..L,
6-pin plug - LS 92/S,
cable 6 m, 3x0,25 mm2 + 1x0,5 mm2 -
LS 92/.., 6000 |
| Light source |
LED (alternating light) |
| Wave lenght |
880 nm |
| Switching frequency |
200 Hz |
Receiver
LED yellow
LED yellow blinkend |
Light path unobstructed
Light path unobstructed, no function reserve |
Transmitter
LED yellow |
Transmitter ON |
| Housing |
Zinc die casting |
| Optical parts |
Glass |
| Weight |
140 g |
| Transmitter activ/not aktiv |
8 V / 2 V or without switches |
| Activation/release delay |
1 ms |
| Input resistance |
4,7 k ± 10 % |
|
|
1) Operating range: recommended Range with functional reserve
2) Limit range: max. possible range without function range
3) LS 92/2.8 Swith npn transistor output (no BWS type 2)
4) Testing voltage 250 V AC
5) 2 = pole reversal protection, 3 = short circuit protection for all outputs |
|
|
Note:
The through-beam safety light barrier is an electro-sensitive protective device in connection with a safety-relevant control system where the cyclical testing of transmitter and receiver is carried out according to EN-/IEC 61496-1, -2, category 2 (testing). The supply unit operating the light barrier must intercept changes and interruption of the supply voltage according to EN-/IEC 61496-1. Minimum diameter of darkening object Ø 13 mm.
|
|
|
|
|
|