LS 92/4.8

Technical Data

Safety Light Barrier
LS 92/4.8
Safety category Type 2 according to EN-/IEC 61496-1,-2 in combination with a test monitoring unit.
Operating range 1) 0 - 12 m
Limit range 2) 0 - 15,6 m
Response time 2,5 ms
Stand-by delay 100 ms
Enclosure rating IP 67, IP 65 for all S-types
Shock proof Semi sine, 30 gn, 11 ms (IEC 947-5-2)
Vibration proof 10 - 55 Hz, max. 7,5 gn (IEC 947-5-2)
Electronic compatibility prEN 50100-1
Ambient temperature (operation/storage) 3) -20 °C ... +60 °C / -30 °C ... +70 °C
External light limit 30 kLux (IEC 947-5-2)
VDE-Protection class I for S-types and cable version
VDE-Protection class 4) II for L-types (M 12 circ. plug-in connection)
Protective cabling 5) 2, 3
Operation voltage UB 10... 30 V DC (residual ripple included)
Residual ripple 15 % von UB
No-load current 35 mA
Switching output 3) pnp transistor output
Output current max. 100 mA
Function bright/dark switching
(by pole reversal of UB)
Signal voltage high/low (UB - 2 V) / 2 V
Connection M12 circular plug-in connection - LS 92/..L,
6-pin plug - LS 92/S,
cable 6 m, 3x0,25 mm2 + 1x0,5 mm2 -
LS 92/.., 6000
Light source LED (alternating light)
Wave lenght 880 nm
Switching frequency 200 Hz
Receiver
LED yellow
LED yellow blinkend

Light path unobstructed
Light path unobstructed, no function reserve
Transmitter
LED yellow

Transmitter ON
Housing Zinc die casting
Optical parts Glass
Weight 140 g
Transmitter activ/not aktiv 8 V / 2 V or without switches
Activation/release delay 1 ms
Input resistance 4,7 k ± 10 %
1) Operating range: recommended Range with functional reserve
2) Limit range: max. possible range without function range
3) LS 92/2.8 Swith npn transistor output (no BWS type 2)
4) Testing voltage 250 V AC
5) 2 = pole reversal protection, 3 = short circuit protection for all outputs

Note:
The through-beam safety light barrier is an electro-sensitive protective device in connection with a safety-relevant control system where the cyclical testing of transmitter and receiver is carried out according to EN-/IEC 61496-1, -2, category 2 (testing). The supply unit operating the light barrier must intercept changes and interruption of the supply voltage according to EN-/IEC 61496-1. Minimum diameter of darkening object Ø 13 mm.