SLSR 95/44.8L

Technical Data

Safety Light Barrier
SLSR 95/44.8L
Safety category Type 2 according to EN-/IEC 61496-1,-2 in combination with a test monitoring unit.
Operating range 1) 0 - 8 m
Limit range 2) 0 - 12 m
Response time 2,5 ms
Stand-by delay 100 ms
Enclosure rating IP 67
Shock proof Semi sine, 30 gn, 11 ms (VDE 0660 T 208)
Vibration proof 10 - 55 Hz, max. 7,5 gn (VDE 0660 T 208)
Electronic compatibility prEN 50100-1
Transmitter active, not active 8 V / 2 V or without switches
Activation/release delay 1 ms
Input resistance 4,7 k ± 10 %
Ambient temperature (operation/storage) 3) -25 °C (-30 °C) ... +60 °C / -40 °C .. .+70 °C
External light limit 20 kLux (VDE 0660 T 208)
Protective cabling 4) 2, 3
VDE-Protection class 5) II, protection isolated
Operation voltage UB 10... 30 V DC (incl. Residual ripple)
Residual ripple 15 % von UB
No-load current 35 mA
Switching output 2 pnp-transistor outputs, antibonding
Output current max. 100 mA
Function bright/dark switching
Signal voltage high/low (UB - 2 V) / 2 V
Connection M 12 circular plug-in connection, high quality
steel 4-pin receiver, 4-pin transmitter
Function bright/dark switching
Weight 90 g
Light source LED (alternating light)
Wave lenght 660 nm
Switching frequency 200 Hz
Receiver
LED green
LED yellow
LED yellow blinkend

Ready for operation
Light path free
Light path free, no functional reserve
Transmitter
LED green
LED yellow

Ready for operation
Transmitter ON
Housing Zinc die casting
Optical parts Glass
1) Operating range: recommended Range with functional reserve
2) Limit range: max. possible range without function range
3) -30° C with constant operating voltage
4) 2 = pole reversal protection, 3 = short circuit protection for all outputs
5) Testing voltage 250 V AC

Note:

The through-beam safety light barrier is an electro-sensitive protective device in connection with a safety relevant control system where the cyclical testing of transmitter and receiver is carried out according to EN-/IEC 61496-1, -2, category 2 (testing). The supply unit operating the light barrier must intercept changes and interruption of the supply voltage according to EN-/IEC 61496-1. Minimum diameter of darkening object Ø 13 mm.