SLSR 95/44.8L
Technical Data
|
|
|
Safety Light Barrier
|
SLSR 95/44.8L
|
| Safety category |
Type 2 according to EN-/IEC 61496-1,-2 in combination with a test monitoring unit. |
| Operating range 1) |
0 - 8 m |
| Limit range 2) |
0 - 12 m |
| Response time |
2,5 ms |
| Stand-by delay |
100 ms |
| Enclosure rating |
IP 67 |
| Shock proof |
Semi sine, 30 gn, 11 ms (VDE 0660 T 208) |
| Vibration proof |
10 - 55 Hz, max. 7,5 gn (VDE 0660 T 208) |
| Electronic compatibility |
prEN 50100-1 |
| Transmitter active, not active |
8 V / 2 V or without switches |
| Activation/release delay |
1 ms |
| Input resistance |
4,7 k ± 10 % |
| Ambient temperature (operation/storage) 3) |
-25 °C (-30 °C) ... +60 °C / -40 °C .. .+70 °C |
| External light limit |
20 kLux (VDE 0660 T 208) |
| Protective cabling 4) |
2, 3 |
| VDE-Protection class 5) |
II, protection isolated |
| Operation voltage UB |
10... 30 V DC (incl. Residual ripple) |
| Residual ripple |
15 % von UB |
| No-load current |
35 mA |
| Switching output |
2 pnp-transistor outputs, antibonding |
| Output current |
max. 100 mA |
| Function |
bright/dark switching |
| Signal voltage high/low |
(UB - 2 V) / 2 V |
| Connection |
M 12 circular plug-in connection, high quality
steel 4-pin receiver, 4-pin transmitter |
| Function |
bright/dark switching |
| Weight |
90 g |
| Light source |
LED (alternating light) |
| Wave lenght |
660 nm |
| Switching frequency |
200 Hz |
Receiver
LED green
LED yellow
LED yellow blinkend |
Ready for operation
Light path free
Light path free, no functional reserve |
Transmitter
LED green
LED yellow |
Ready for operation
Transmitter ON |
| Housing |
Zinc die casting |
| Optical parts |
Glass |
|
|
1) Operating range: recommended Range with functional reserve
2) Limit range: max. possible range without function range
3) -30° C with constant operating voltage
4) 2 = pole reversal protection, 3 = short circuit protection for all outputs
5) Testing voltage 250 V AC |
|
|
Note:
The through-beam safety light barrier is an electro-sensitive protective device in connection with a safety relevant control system where the cyclical testing of transmitter and receiver is carried out according to EN-/IEC 61496-1, -2, category 2 (testing). The supply unit operating the light barrier must intercept changes and interruption of the supply voltage according to EN-/IEC 61496-1. Minimum diameter of darkening object Ø 13 mm.
|
|
|
|
|
|