SLS 96 M...

Technical Data

Safety Light Barrier
SLS 96 M
Safety category Type 2 according to EN 61496-1,-2 in combination with a test monitoring unit.
Operating range 1) Infrared light 0 - 50 m, red light 0 - 30 m
Limit range 2) Infrared light 0 - 65 m, red light 0 - 39 m
Sensor response time 1 ms
Stand-by delay 200 ms
Enclosure rating IP 67
Shock resistance Semi sine, 30 gn, 11 ms (VDE 0660 T 208)
Vibration resistance 10 - 55 Hz, max. 7,5 gn (VDE 0660 T 208)
Electronic compatibility Focus degree 3 (IEC 801.2...4)
Ambient temperature (operation/storage) -20 °C ... +60 °C / -40 °C .. +70 °C
External light limit 10 kLux (VDE 0660 T 208)
Protective cabling 3) 1, 2, 3
VDE-Protection class 4) II, protection isolated
Operation voltage UB 10... 30 V DC (residual ripple included)
Residual ripple 15 % von UB
No-load current 50 mA
Switching output pnp transistor output
Output current max. 100 mA
Function bright switching
Signal voltage high/low (UB - 2 V) / 2 V
Connection Terminals or M12 circular plug-in connection
Light source LED (alternating light)
Wave lenght Infrared light 880 nm, red light 660 nm
Switching frequency sensor 500 Hz
LED green Ready for operation
Receiver
LED yellow
LED yellow, flashing

Light path unobstructed
Light path unobstructed, no function reserve
Transmitter
LED yellow

Transmitter activated
Housing Metal housing: Zinc die casting
Plastic housing: polycarbonat
Optical parts Metal housing: Glass
Plastic housing: plastic
Weight Metal housing: 380 g
Plastic housing: 150 g
Transmitter activ/not activ 8 V / 2 V
Activation/release delay 1 ms
Input resistance 10 k ± 10 %
Lens heating system Prevents steaming up and offers protection in case of changes in temperature
Low temperature As low as -35 °C

1) Operating range: recommended Range with functional reserve
2) Limit range: max. possible range without function range
3) 1 = transient protection, 2 = pole reversal protection, 3 = short circuit protection for all outputs
4) Testing voltage 250 V AC

Note:

The through-beam safety light barrier is an electro-sensitive protective device only in connection with a safety-relevant control system where the cyclical testing of transmitter and receiver is carried out according to EN-/IEC61496-1, -2, category 2 (testing).

Supply unit operating light barrier must intercept changes and interruption of the supply voltage according to prEN 50100-1.