COMPACT EX1

Safety Light Curtains


COMPACT EX1 - Safety Light Curtains
CE TÜV Ex protection LCIE - Bureau Veritas

Point of operation guarding: Light Curtain with finger resolution Point of operation guarding: Light Curtain with hand resolution Access guarding: Light Curtain

Devices and protective systems must meet special requirements with use in explosion-risk areas.

Built into pressure-resistant glass cylinders of the Ex protection type "d" under the name COMPACT EX1, various models of the COMPACT Safety Light Curtains are available, tailor-made for these types of applications, i.e. for use up to Ex zone 1 (gases) and Ex zone 21 (flammable dusts) – with the typical benefits of the COMPACT series with regard to higher interference immunity and availability. In addition to the requirements of machine safety, COMPACT EX1 also satisfies the provisions of ATEX Directive 94/9/EC.

The glass cylinder housed in the COMPACT Safety Light Curtain is firmly closed with a lid. Robust cable bushings in the lid safely enclose the cables suitable for explosion-risk areas, which are to be provided by the customer. COMPACT EX1 can be used in industrial applications, however it cannot be used in pits. The device complies as an electrical piece of apparatus of EX device group II, EX category 2.


Special features
  • Type 4, suitable for safety category 4

  • Complies with ATEX Directive 94/9/EC (ATEX Directive)

  • Fault-free operation of adjacent devices with selection of different transmission channels

  • Maintenance-free with safety transistor outputs (OSSDs)

  • Ignition protection type "d" pressure-encapsulated

  • Temperature class, T6

Important technical data, overview
Type in accordance with IEC/EN 61496 Type 4
SIL in accordance with IEC 61508 and
IEC/EN 62061
SIL 3
Performance Level (PL) in accordance with EN ISO 13849-1 PL e
Category in accordance with EN ISO 13849 and EN 954-1 4
Resolution 14 mm 30 mm
Range 0...6 m 0...18 m
SingleScan response time 17...33 ms 9...17 ms
Protective field height 750, 1050, 1500 mm 750, 1050, 1500 mm
Protective housing diameter Approx. 150 mm
Safety-related switching outputs (OSSDs) 2 pnp transistor outputs
Connection system Cable gland
Ex device group II
Ex device category 2
Temperature class, gases T6
Permissible ignition temperature T > 85 °C
Ignition protection type "d" pressure-encapsulated