COMPACTplus/AS-i
Safety Light Curtains
 |
| Special features |
- Type 4 Safety Light Curtain in accordance with IEC/EN 61496-1/-2
- Integrated AS-Interface, bus connection via the AC-PDA1/A, adapter for AS-i data transfer and separate 24-volt power supply
- Safe data transfer of the OSSD signals via AS-Interface
- Device swap-out without PC via SERVICE function of the AS-i Safety Monitor
- Additional diagnostics information via AS-Interface, e.g. Muting sensors status, Muting or weak signal display
- Several devices can be cascaded (COMPACTplus-b, COMPACTplus-i)
- Direct connection of Muting sensors, start/restart button or lamp directly on the device via sensor connection module (COMPACTplus -m)
|
|
| Important technical data, overview |
| Type in accordance with IEC/EN 61496 |
4 |
SIL in accordance with IEC 61508 and
IEC/EN 62061 |
3 |
| Performance Level (PL) in accordance with EN ISO 13849-1 |
e |
| Category in accordance with EN ISO 13849 and EN 954-1 |
4 |
| Resolution (type-dependent) |
14 mm |
30 mm |
50 mm |
90 mm |
| Range |
0...6 m |
0...18 m |
0...18 m |
0...18 m |
| Protective field height (type-dependent) |
150...3000 mm |
| Profile cross-section |
52 mm x 55 mm |
| Safety-related switching output (OSSD) |
AS-i Safety Interface |
| Connection system |
M12 plug (AS-i Safety) |
| AS-i profile |
S-7.B.1, safe slave |
| Slave address |
1...31, programmable (factory setting = 0) |
| Cycle time in accordance with AS-i specifications |
5 ms |
| Current consumption from AS-i circuit |
50 mA |
| Sensor response time |
10 to 66 ms |
| Restart delay time |
20...5000 ms, can be set with SafetyLab software, presetting 100 ms (after protective field release) |
|
|
|