COMPACTplus-i Safety Light Curtains

Technical data

General system data
Type in accordance with IEC/EN 61496 4
SIL in accordance with IEC 61508 and IEC/EN 62061 3
Performance Level (PL) in accordance with EN ISO 13849-1 e
Probability of dangerous failure per hour (PFHD) For protective heights up to 900 mm, all resolutions 1.90 x 10-8 1/h
For protective heights up to 1800 mm, all resolutions 2.26 x 10-8 1/h
For protective heights up to 3000 mm 2.67 x 10-8 1/h
Service life (TM) in accordance with EN ISO 13849-1 20 years
Number of cycles until dangerous failure (B10d) in accordance with EN 61810-2 (applies for all R-variants) With DC1 (ohmic load) On request
With AC1 (ohmic load) On request
With DC13 (inductive load) 630,000 (5 A, 24 V)
With AC15 (inductive load) 1,480,000 (3 A, 230 V)
Low load (20% nominal load) On request
Resolution 14 mm 30 mm
Range 0...6 m 0...18 m
Response time Transistor output 5...41 ms 5...22 ms
Relay output 20...56 ms 20...37 ms
AS-i Safety Interface 10...46 ms 10...27 ms
PROFIsafe interface 25...61 ms 25...62 ms
Protective field height 150...1800 mm 150...1800 mm
Supply voltage 24 V DC, ±20 %
Connection cable length max. 100 m at 1.0 mm 2
Safety class III and I (depending on model)
Protection rating IP 65*
Temperature range, operation 0...+50° C
Temperature range, storage -25...+70° C
Relative humidity 15...95 %
Profile cross-section 52 mm x 55 mm
Weight per device (length-dependent) 0.70...5.10 kg
Transmitter
Transmitter diodes, class in accordance with EN 60825 1
Wavelength 880 nm
Current consumption 75 mA
Connection system Cable gland (M20) Hirschmann plug (DIN 43651), 12-pin MIN-style plug (MIN series), 3-pin M12 plug, 5-pin
Receiver
Current consumption 160 mA without external load
Safety-related switching outputs (OSSDs) 2 PNP transistor outputs (short-circuit proof, cross circuit monitored) 2 relay outputs (normal open contacts) AS-i Safety interface PROFIsafe interface
Switching voltage high active Min. Uv -1.0 V
Switching voltage low max. +2.5 V
Switching current Typical, 500 mA
Connection system Cable gland (T1: M20, R1: M25) Hirschmann plug (DIN 43651), T2: 12-pin, R2: 12-pin MIN-style plug (MIN series), T3: 7-pin, R3: 12-pin M12 plug (safety bus systems), 5-pin, R4: 8-pin

*) Without additional measures the devices are not suited for outdoor use.