COMPACTplus-m

Safety Light Curtains


COMPACTplus-m - Safety Light Curtains
CE TÜV UL listed IP 65

Point of operation guarding: Light Curtain with finger resolution Point of operation guarding: Light Curtain with hand resolution Danger zone guarding: Light Curtain Access guarding: Light Curtain

The proper, specification-compliant, time-restricted bridging of a protective device (Muting) is required in numerous instances for a continuous, and therefore efficient production process, when conveyor vehicles, work pieces or palettes have to pass a protective field without interrupting the process, for example. The COMPACTplus-m type 4 Safety Light Curtains in accordance with IEC/EN 61496 are predestined for these requirements. They have integrated Muting functions and, controlled by Muting sensors, they can therefore be switched inactive. After the relevant objects have passed by the safety function is automatically activated again.

COMPACTplus Safety Light Curtains and Multiple Light Beam Safety Devices can be equipped with various functions to optimally perform specific tasks with regard to higher functionality, more flexible integration and easier operability. The COMPACTplus series have a start/restart interlock, contactor monitoring and additional functions that can be easily activated with switches. External additional modules are therefore no longer required.

Specific settings are made with the diagnostics and parametering software, SafetyLab. COMPACTplus can be connected to both conventional safety modules and to open safety bus systems via various interfaces (transistor/relay output, AS-Interface Safety at Work , PROFIsafe). These safety sensors can therefore be flexibly integrated into existing automation environments.


Special features
  • Plug-in module with saved device parameters for fast device swap-out

  • M12 local connection socket for connecting local sensors and signal devices

  • Local connection box and Y-cable (accessories) simplify sensor wiring


Important technical data, overview
Type in accordance with IEC/EN 61496 4
SIL in accordance with IEC 61508 and
IEC/EN 62061
3
Performance Level (PL) in accordance with EN ISO 13849-1 e
Category in accordance with EN ISO 13849 4
Resolution 14 mm 30 mm 50 mm 90 mm
Range 0...6 m 0...18 m 0...18 m 0...18 m
Protective field height (type-dependent) 150 ... 3000 mm
Profile cross-section 52 mm x 55 mm
Safety-related switching outputs (OSSDs) 2 PNP transistor outputs, 2 relay outputs
AS-i Safety interface PROFIsafe interface
Connection system Cable gland Hirschmann plug MIN-style plug M12 plug

Functions
Start/restart interlock (RES), selectable
Dynamic contactor monitoring (EDM), selectable
2 transmission channels, selectable
2 or 4-sensor Parallel Muting
Muting restart override function
Output for Muting indicator

Functions extension with "SafetyLab" PC software (accessories)
Infrared interface for parametering and diagnostics
More Muting types, parameterizable Muting time limit
Additional control signals for Muting and Muting timer
Reduced resolution can be set
Partial Muting can be parametered
Muting indicator function can be parametered
Beam signals for position and height measuring
Additional 2-channel safety circuit, e.g. for door switches