| General system data |
| Type in accordance with IEC/EN 61496 |
Type 2 |
| SIL in accordance with IEC 61508 and IEC/EN 62061 |
2 |
| Performance Level (PL) in accordance with EN ISO 13849-1 |
d |
| Probability of a failure to danger per hour (PFHD) |
For protective heights up to 900 mm, all resolutions |
8.18 x 10-8 1/h |
| For protective heights up to 1800 mm, all resolutions |
8.92 x 10-8 1/h |
| For protective heights up to 2850 mm |
On request |
| Service life (TM) in accordance with EN ISO 13849-1 |
20 years |
| Category in accordance with EN ISO 13849 and EN 954-1 |
2 |
| Resolution |
20 mm |
30 mm |
40 mm |
90 mm |
| Range |
0.5...15 m |
0.2...10 m |
0.8...20 m |
0.8...20 m |
| Response time (depends on protective field height) |
9...60 ms |
7...31 ms |
7...31 ms |
8...12 ms |
| Protective field height |
150...1800 mm |
|
|
600...1800 mm |
| Synchronization |
Optical via transmitter and receiver |
| Supply voltage |
24 V DC, ± 20 % |
| Test repetition time with internal testing |
100 ms |
| Connection cable length |
Max. 100 m with 0.25 mm² |
| Safety class |
III |
| Protection rating |
IP 65 |
| Temperature range, operation |
0...+50 °C |
| Temperature range, storage |
-25...+70 °C |
| Relative humidity |
15...95 % |
| Profile cross-section |
30 mm x 34 mm |
| Weight per device (length-dependent) |
0.30...1.90 kg |
| Transmitter |
| Transmitter diodes, class in accordance with EN 60825 |
1 |
| Wavelength |
950 nm |
| Current consumption |
75 mA |
| Connection system |
M12 plug, 5-pin |
| External test input |
24 V DC, max. 20 mA |
| Receiver |
| Current consumption |
140 mA without external load |
| Safety-related switching outputs (OSSDs) |
2 pnp transistor outputs (short circuit-proof, cross-circuit monitored) |
| Switching voltage high active |
min. Uv -1.9 V |
| Switching voltage low |
max. 1 V |
| Switching current |
max. 250 mA |
| Cable length |
max. 100 m with 0.25 mm² |
| SOLID-2 connection system |
M12 plug, 5-pin |
| SOLID-2E connection system |
M12, 8-pin |
| SOLID-2E signal inputs on BA1 and BA2 |
24 V DC, max. 10 mA |