SOLID-2

Electrical Connection

Transmitter and Receiver Standard are equipped with M12, 5-pin plugs while the Receiver Extended providing additional functions is equipped with a M12, 8-pin plug.

Transmitter, connection assignment
Transmitter, connection assignment
Pin Color Assignment Inputs/outputs
1 brown Supply voltage +24V DC for TC1 or 0V for TC2
2 white   nc  
3 blue Supply voltage 0V for TC1 or +24V DC for TC2
4 black Test in Test input
Connected to +24V DC
internal test activated
Connected to 0V or disconnected
external test activated
5 grey/
connector
enclosure
Shield Functional earth
Receiver Standard, connection assignment
Receiver Standard, connection assignment
Pin Color Assignment Inputs/outputs
1 brown Supply voltage +24V DC for TC1 or 0V for TC2
2 white Output OSSD2, switching semicontactor output
3 blue Supply voltage 0V for TC1 or +24V DC for TC2
4 black Output OSSD1, switching semicontactor output
5 grey/
connector
enclosure
Shield Functional earth
Receiver Extended, connection assignment
Receiver Extended, connection assignment
Pin Color Assignment Inputs/outputs
1 white Operating mode selection Input BA1
2 brown Supply voltage +24V DC for TC1 or 0V for TC2
3 green Operating mode selection Input BA2
4 yellow   nc  
5 grey Output OSSD1, switching semicontactor output
6 pink Output OSSD2, switching semicontactor output
7 blue Supply voltage 0V for TC1 or +24V DC for TC2
8 black/
connector
enclosure
Shield Functional earth
Connection example, Receiver Standard, internal cyclical testing,
transmission channel 1 using MSI-SR2/F, with S/R, with EDM
Connection example, Receiver Standard, internal cyclical testing, transmission channel 1 using MSI-SR2/F, with S/R, with EDM
a) EDM feedback loop
b) Positive-driven relays or contactors,
suitable spark suppression required
c) Switching off path with two-channel control*
d) Switching off path with one-channel control*
e) Internal testing selected
f) Polarity selected for transmission channel 1
g) Start/restart button
*) In general both of the contacts must be used.
Receiver Extended, internal cyclical testing, transmission channel 1,
with RES, with EDM
Receiver Extended, internal cyclical testing, transmission channel 1, with RES, with EDM
a) EDM feedback loop
b) Positive-driven relays or contactors,
suitable spark suppression required
c) Switching off path with two-channel control*
d) Switching off path with one-channel control*
e) Internal testing selected
f) Polarity selected for transmission channel 1
g) Start/restart button
*) In general both of the contacts must be used.