General system data
|
| Performance Level (PL) in accordance with EN ISO 13849-1 |
On request |
| Category in accordance with EN ISO 13849 |
Up to 4 (depending on the category of the upstream protective device) |
| Service life (TM ) in accordance with EN ISO 13849-1 |
On request |
| Probability of a failure to danger per hour (PFHd) |
On request |
| Number of cycles until 10 % of the components have a failure to danger (B10d)* |
with DC1 (ohmic load) |
On request |
| with AC1 (ohmic load) |
| with DC13 (inductive load) |
| with AC15 (inductive load) |
| Low load (20% nominal load) |
| Mean time to dangerous failure (MTTFd) in accordance with EN ISO 13849-1 |
On request |
| Stop category in accordance with IEC/EN 60204-1 |
0 |
| Supply voltage |
24 V AC/DC -15 % to +10 % |
| Power consumption |
2.1 W (AC) / 1.9 W (DC) |
| Safety-related switching outputs (OSSDs) |
2 relay outputs (NO) |
| Signal output |
Relay output (NC) |
| Continuous current per current path |
max. 3 A |
| Response time |
20 ms |
| Restart delay time |
50 ms |
| Time window for simultaneity monitoring |
Max. 0.5 s |
| Admissible input line resistance |
<70 |
| Temperature range, operation |
-25...+55 ° C |
| Protection rating |
IP 20 |
| Connection system |
Screw terminals |
| Dimensions (W x H x D) |
22.5 mm x 99 mm x 113.6 mm |
| Mounting |
on 35 mm DIN rail |