| Important technical data, overview |
| Category in accordance with EN ISO 13849-1 |
Up to 4 (depending on the number of connected sensors) |
| Performance Level (PL) in accordance with EN ISO 13849-1 |
Up to e (depending on the number of connected sensors) |
| Stop category in accordance with EN 60204-1, EN 13850 |
STOP 0 |
| Supply voltage |
24 V AC/DC, +/- 10 %, SELV |
Output contacts, OSSDs
OSSD protective circuit |
2 normal open contacts (N/O), 1 normal closed contact (N/C)
Provide suitable spark extinction (via relays, contactors) |
| Regression delay, response time |
20 ms |
Temperature range, operation
Relative humidity (non-condensing) |
0 ... +55 ° C
4 % ...100 % |
Temperature range, storage
Relative humidity (non-condensing) |
-25 ... +70 ° C
5 % ...95 % |
| Dimensions (W x H x D) |
22.5 mm x 99 mm x 113.6 mm |