MSI-RM2 - Safety Relays

Technical data

General system data

Category in accordance with EN ISO 13849 Up to 4 (depending on the category of the upstream protective device)
Service life (TM ) in accordance with EN ISO 13849-1 On request
Number of cycles until 10 % of the components have a failure to danger (B10d)* with DC1 (ohmic load) 125,000
with AC1 (ohmic load) 125,000
with DC13 (inductive load) 40,000 (2 A, 24 V)
with AC15 (inductive load) 60,000 (2 A, 24 V)
Low load (20% nominal load) 1,860,000
Supply voltage 24 V DC ±20 % (via OSSDs of the connected AOPD)
Power consumption 1.5 W (supply via AOPD)
Safety-related switching outputs (OSSDs) 2 relay outputs (changeover)
Signal output Relay output (NC)
Continuous current per current path max. 3 A
Response time 10 ms
Restart delay time 20 ms
Current consumption (inputs B1 and B3) 32 mA each
Admissible input line resistance 50
Temperature range, operation 0...+50 °C
Temperature range, storage -25...+70 °C
Safety class II
Protection rating IP 20
Connection system Screw terminals
Dimensions (W x H x D) 17.5 mm x 99 mm x 113.6 mm
Mounting on 35 mm DIN rail