| General system data |
| Switch type |
Interlock device without guard interlocking in accordance with EN 1088 |
| Service life (TM) in accordance with EN ISO 13849-1 |
20 years |
| Number of cycles until 10 % of the components have a failure to danger (B10d) |
2,000,000 |
| Temperature range, operation |
-25...+80 °C |
| Dirt levels, external, in accordance with EN 60947-1 |
3 |
| Housing material |
Metal |
| Actuator, external |
AC-AHxx series, straight, angled, resilient, alignable |
| Dimensions |
See dimensional drawing |
| Protection rating |
IP 67 |
| Contact protection |
Earthing |
| Approach actuation directions |
1 x above, 4 x side (90°) |
| Mechanical life time in accordance with IEC 6047-5-1 |
1x106 actuation cycles |
| Actuation frequency in accordance with IEC 6047-5-1 |
Max. 3,600 activations an hour |
| Approach speed |
Max. 0.5 m/s |
| Actuation force (extraction) |
10 N |
| Actuating path with forced separation |
Min. 10.2 mm |
S200-M3C1-M20 |
| Min. 8.6 mm |
S200-M1C1-M20 |
| Min. 8.8 mm |
S200-M4C1-M20 |
| Recoil tolerance |
5 mm |
| Contact allocation |
2NC  |
S200-M3C1-M20 |
1NC + 1NO |
S200-M1C1-M20 |
2NC + 1NO |
S200-M4C1-M20 |
| Switching principle |
Creep contact |
| Contact opening |
Force-fit |
| Contact material |
Silver alloy |
| Usage category in accordance with EN 60947-5-1 |
AC 15: Ue / Ie: 250 V / 6 A, 400 V / 4 A, 500 V / 1 A
DC 13: Ue / Ie: 24 V / 6 A, 125 V / 1.1 A, 250 V / 0.4 A |
| Rated insulation voltage |
500 V AC, 600 V DC |
| Conventional thermal current |
Max. 10 A |
| Short-circuit protection in accordance with IEC60269-1 |
500 V, 10 A, type aM |
| Connection system |
Number of cable entries |
1 |
| Type of cable entries |
M20 x 1.5 |
| Cable cross-section (wire) |
1 x 0.5 mm² to
2 x 2.5 mm² |