TNT 35
Configurable Safety Relays
 |
TNT 35 is a Test Monitoring Unit for the periodic testing of "testable" opto-electronic protective devices.
Both components, sensor and TNT 35, form an AOPD in accordance with IEC/EN 61496-1, -2. Up to 6 type 2 sensors can be connected to the TNT 35 via a series connection.
In addition to testable Leuze electronic type 2 Single Light Beam Safety Devices, type 2 Single Light Beam Safety Devices of the MLD 300 series can also be connected. The machine’s functional sequence remains unimpaired by the periodic internal function tests.
|
| Special features |
- Constant cyclical testing every 2 s without process interruption of the machine function during the test
- 2 Safety Relay outputs with internal monitoring
- Selectable start and restart interlock status
- Selectable integrated contactor monitoring (EDM)
- LED indicators for all important functions and operating states.
- Low space-requirement in the cabinet with compact construction
|
| Important technical data, overview |
| Type in accordance with IEC/EN 61496 |
Type 2 |
| Performance Level (PL) in accordance with EN ISO 13849-1 |
PL d |
| Category in accordance with EN ISO 13849 |
2 |
| Stop category in accordance with IEC/EN 60204-1 |
0 |
| Supply voltage |
24 V DC, ±15 % |
| Response time |
< 20 ms |
| Interval for periodic testing |
2 s |
| Max. number of type 2 sensors in series connection |
6 (total response time of the sensor series connection, 60 ms) |
| Safety-related switching outputs (OSSDs) |
2 relay outputs (NO) |
| Temperature range, operation |
-20...+60 ° C |
| Temperature range, storage |
-30... +70 °C |
| Dimensions (W x H x D) |
45 mm x 99 mm x 113.6 mm |
| Functions |
| Test Monitoring Unit for periodic testing of type 2 sensors |
| Multiple monitoring of type 2 sensors with series connection |
| Start/restart interlock (RES), optionally with/without |
| Static contactor monitoring (EDM), with/without optional |
| "Safety on" signal output |
| "Error" signal output |
|
|
|