RSL235-S/12-M12
Safety laser scanner
Series | RSL 200 |
Application | Mobile danger zone guarding Stationary danger zone guarding Vehicle navigation |
Functions | Contactor monitoring (EDM) Field triple changeover Field triple monitoring Fixed selection of one field triple |
Restart | Automatic start/restart Start/restart interlock (RES) Start interlock/automatic restart |
Type | 3, IEC/EN 61496 |
SIL | 2, IEC 61508 |
SILCL | 2, IEC/EN 62061 |
Performance Level (PL) | d, EN ISO 13849-1 |
PFHD | 2E-08 per hour |
Mission time | 20 years, EN ISO 13849-1 |
Category | 3, EN ISO 13849 |
Resolution (adjustable) | 50/70 mm |
Number of field triples, switchable | 32 Piece(s) |
Number of protective functions | 1 Piece(s) |
Diffuse reflection, min. | 1.8 % |
Operating range | 0 ... 3 m |
Number of warning fields per field triple | 2 Piece(s) |
Operating range | 0 ... 15 m |
Object size | 150 mm x 150 mm |
Diffuse reflection, min. | 20 % |
Light source | Laser Laser,Infrared |
Wavelength | 905 nm |
Laser class | 1, IEC/EN 60825-1:2014 |
Transmitted-signal shape | Pulsed |
Repetition frequency | 96 kHz |
Angular resolution | 0.2 ° |
Scanning angle | 275 ° |
Detection range | 0 ... 25 m, Diffuse reflection > 90% |
Distance resolution, radial | 2 mm |
Distance resolution, lateral | 0.2 ° |
Systematic measurement error Dmeas - Dreal | min.: -20 mm typ.: -10 mm max.: 0 mm (Diffuse reflection: 1.8% … retro-reflector Measurement range: 0.2 … 25 m) |
Measurement value noise | 10 mm 1 σ (• Diffuse reflection: 1.8% … 20% Measurement range: 0 … 9 m • Diffuse reflection: 20% … retro-reflector Measurement range: 0 … 25 m) |
Laser spot (H x W), 5 m | 63 mm x 8 mm |
Laser spot (H x W), 15 m | 188 mm x 23 mm |
Laser spot (H x W), 25 m | 318 mm x 38 mm |
Protective circuit | Cross circuit protection Overvoltage protection |
Supply voltage UB | 24 V, DC, -30 ... 20 % |
Current consumption (without load), max. | 300 mA, (use power supply unit with 1 A) |
Power consumption, max. | 7 W, For 24 V, plus output load |
Number of signal outputs, configurable | 8 Piece(s) |
Number of safety-related switching outputs (OSSDs) | 2 Piece(s) |
Type | Safety-related switching output OSSD |
Switching voltage high, min. | 22.2 V |
Switching voltage low, max. | 3 V |
Voltage type | DC |
Switching current, max. | 85 mA |
Switching element | Transistor, PNP |
Switching element | Transistor, PNP |
Response time | ≥ 75 ms |
Type | Bluetooth, Ethernet, USB 2.0 |
Function | Configuration/parametization Diagnosis Display of the measurement contour Protective field definition and warning field definition |
Connection | M12 connector, 4-pin, D-coded |
Function | Configuration/parametization Diagnosis Protective field definition and warning field definition |
Frequency band | 2,400 ... 2,483.5 MHz |
Radiated transmitting power | Max. 4.5 dBm (2.82 mW), class 2 |
Function | Configuration/parametization Diagnosis Protective field definition and warning field definition |
Connection | USB 2.0 type C, socket |
Transmission speed, max. | 12 Mbit/s |
Cable length | ≤ 5m Longer cable lengths are possible using active cables. |
Number of connections | 3 Piece(s) |
Function | Machine interface |
Type of connection | Connector |
Thread size | M12 |
Type | Male |
Material | Metal |
No. of pins | 12 -pin |
Encoding | A-coded |
Function | Data interface Measurement value transmission via UDP (signal strength, distance and process image) |
Type of connection | Connector |
Thread size | M12 |
Type | Female |
Material | Metal |
No. of pins | 4 -pin |
Encoding | D-coded |
Function | Configuration interface |
Type of connection | USB |
Connector type | USB 2.0 type C |
Dimension (W x H x L) | 80 mm x 80 mm x 86 mm |
Housing material | Metal Plastic |
Metal housing | Diecast zinc |
Plastic housing | PC |
Lens cover material | Plastic |
Net weight | 600 g |
Housing color | Black Gray Yellow, RAL 1021 |
Type of fastening | Mounting plate Through-hole mounting Via optional mounting device |
Type of display | LED |
Number of LEDs | 5 Piece(s) |
Type of configuration | Software Sensor Studio |
Ambient temperature, operation | 0 ... 50 °C |
Ambient temperature, storage | -20 ... 60 °C |
Relative humidity (non-condensing) | 15 ... 95 % |
Degree of protection | IP 65 |
Protection class | III |
Approvals | TÜV Süd |
Test procedure for oscillation in accordance with standard | IEC/EN 60068-2-6 |
Test procedure for continuous shock in accordance with standard | IEC 60068-2-29, test Eb |
Customs tariff number | 85365019 |
ECLASS 5.1.4 | 27272705 |
ECLASS 8.0 | 27272705 |
ECLASS 9.0 | 27272705 |
ECLASS 10.0 | 27272705 |
ECLASS 11.0 | 27272705 |
ECLASS 12.0 | 27272705 |
ECLASS 13.0 | 27272705 |
ECLASS 14.0 | 27272705 |
ECLASS 15.0 | 27272705 |
ETIM 5.0 | EC002550 |
ETIM 6.0 | EC002550 |
ETIM 7.0 | EC002550 |
ETIM 8.0 | EC002550 |
ETIM 9.0 | EC002550 |
ETIM 10.0 | EC002550 |