ELC110R17-300

Safety light curtain receiver

Part no.: 72001103

Icon Icon Icon Icon Icon
Series ELC100
Device type Receiver
Contains 2x sliding block
Application Finger protection
Functions Automatic start/restart
Type 4, IEC/EN 61496
SIL 3, IEC 61508
SILCL 3, IEC/EN 62061
Performance Level (PL) e, EN ISO 13849-1
PFHD 8E-09 per hour
Mission time 20 years, EN ISO 13849-1
Category 4, EN ISO 13849
Resolution 17 mm
Protective field height 300 mm
Synchronization Optical between transmitter and receiver
Protective circuit Overvoltage protection, Short circuit protected
Supply voltage UB 24 V, DC, -20 ... 20 %
Current consumption, max. 100 mA
Number of safety-related switching outputs (OSSDs) 2 Piece(s)
Type Safety-related switching output OSSD
Switching voltage high, min. 18 V
Switching voltage low, max. 2.5 V
Switching voltage, typ. 22.5 V
Voltage type DC
Current load, max. 50 mA
Load inductivity 500,000 µH
Load capacity 0.03 µF
Residual current, max. 0.5 mA
Voltage drop 1.5 V
Switching principle +24 V switching
Switching element Transistor, PNP
Switching principle +24 V switching
Switching element Transistor, PNP
Response time 5.6 ms
Restart delay time 100 ms
Number of connections 1 Piece(s)
Function Machine interface
Type of connection Connector
Thread size M12
Type Male
Material Metal
No. of pins 4 -pin
Permissible conductor cross section, typ. 0.25 mm²
Length of connection cable, max. 15 m
Permissible cable resistance to load, max. 20 Ω
Dimension (W x H x L) 34.7 mm x 315 mm x 39.3 mm
Housing material Metal
Metal housing Aluminum
Lens cover material Plastic / PMMA
Material of end caps Diecast zinc
Net weight 530 g
Housing color Yellow, RAL 1021
Type of fastening Mounting bracket, Groove mounting
Type of display LED
Number of LEDs 6 Piece(s)
Ambient temperature, operation 0 ... 55 °C
Ambient temperature, storage -30 ... 70 °C
Relative humidity (non-condensing) 0 ... 95 %
Degree of protection IP 65
Protection class III
Certifications TÜV Süd, c CSA US
Vibration resistance 50 m/s²
Test procedure for oscillation in accordance with standard IEC/EN 60068-2-6
Test procedure for shock in accordance with standard IEC/EN 60068-2-6
US patents US 6,418,546 B
Customs tariff number 85365019
ECLASS 8.0 27272704
ECLASS 9.0 27272704
ECLASS 10.0 27272704
ECLASS 12.0 27272704
ETIM 5.0 EC002549
ETIM 6.0 EC002549
ETIM 7.0 EC002549
Results list: 1 products found
ELC100T17-300
Safety light curtain transmitter
Part no.: 72000103
  • Series: ELC100
  • Application: Finger protection
  • Type: 4, IEC/EN 61496
  • Operating range: 0.5 ... 3 m
Part no.: 72000103
Results list: 7 products found
MSI 410-01
Safety control
Part no.: 50132984
  • Type: Safety control
  • Number of inputs: 20 Piece(s)
  • Number of outputs: 4 Piece(s)
  • Type of terminal: Screw terminal
Part no.: 50132984
MSI 420-01
Safety control
Part no.: 50132986
  • Type: Safety control
  • Number of inputs: 16 Piece(s)
  • Number of outputs: 8 Piece(s)
  • Type of terminal: Screw terminal
Part no.: 50132986
MSI 430-01
Safety control
Part no.: 50132988
  • Type: Safety control
  • Number of inputs: 16 Piece(s)
  • Number of outputs: 8 Piece(s)
  • Type of terminal: Screw terminal
Part no.: 50132988
MSI-SR-LC21-01
Safety relay
Part no.: 50133008
  • Application: Base device for E-Stop and safety door application...
  • Restart: Automatic, Manual
  • Type of terminal: Screw terminal
  • Functions: Monitoring of solenoid switches, Monitoring of E-S...
Part no.: 50133008
MSI-SR-LC31MR-01
Safety relay
Part no.: 50133006
  • Application: Base device for E-Stop and safety door application...
  • Restart: Manual
  • Type of terminal: Screw terminal
  • Functions: Monitoring of solenoid switches, Monitoring of E-S...
Part no.: 50133006
MSI-SR4B-01
Safety relay
Part no.: 547950
  • Restart: Automatic, Manual
  • Type of terminal: Screw terminal
  • Functions: Cross circuit monitoring, Automatic start/restart,...
  • Contacts: 3 NO contacts / 1 NC contact
Part no.: 547950
MSI-SR5B-01
Safety relay
Part no.: 547952
  • Restart: Automatic, Manual
  • Type of terminal: Screw terminal
  • Functions: Double sensor monitoring, Automatic start/restart,...
  • Contacts: 2 NO contacts / -
Part no.: 547952

Filter

Results list: 9 products found
KD S-M12-5A-P1-050
Connection cable
Part no.: 50133860
  • Connection: Connector, M12
  • Version: Axial, Female
  • No. of pins: 5 Piece(s)
  • Cable length: 5,000 mm
Part no.: 50133860
KD U-M12-4A-P1-020
Connection cable
Part no.: 50130654
  • Connection: Connector, M12
  • Version: Axial, Female
  • No. of pins: 4 Piece(s)
  • Cable length: 2,000 mm
Part no.: 50130654
KD U-M12-4A-P1-050
Connection cable
Part no.: 50130657
  • Connection: Connector, M12
  • Version: Axial, Female
  • No. of pins: 4 Piece(s)
  • Cable length: 5,000 mm
Part no.: 50130657
KD U-M12-4A-P1-100
Connection cable
Part no.: 50130658
  • Connection: Connector, M12
  • Version: Axial, Female
  • No. of pins: 4 Piece(s)
  • Cable length: 10,000 mm
Part no.: 50130658
KD U-M12-4A-P1-150
Connection cable
Part no.: 50142371
  • Connection: Connector, M12
  • Version: Axial, Female
  • No. of pins: 4 Piece(s)
  • Cable length: 15,000 mm
Part no.: 50142371
KD U-M12-5A-P1-020
Connection cable
Part no.: 50133839
  • Connection: Connector, M12
  • Version: Axial, Female
  • No. of pins: 5 Piece(s)
  • Cable length: 2,000 mm
Part no.: 50133839
KD U-M12-5A-P1-030
Connection cable
Part no.: 50133840
  • Connection: Connector, M12
  • Version: Axial, Female
  • No. of pins: 5 Piece(s)
  • Cable length: 3,000 mm
Part no.: 50133840
KD U-M12-5A-P1-050
Connection cable
Part no.: 50133841
  • Connection: Connector, M12
  • Version: Axial, Female
  • No. of pins: 5 Piece(s)
  • Cable length: 5,000 mm
Part no.: 50133841
KD U-M12-5A-P1-100
Connection cable
Part no.: 50132534
  • Connection: Connector, M12
  • Version: Axial, Female
  • No. of pins: 5 Piece(s)
  • Cable length: 10,000 mm
Part no.: 50132534
Results list: 1 products found
UM60-300
Deflecting mirror
Part no.: 529603
  • Mirror length: 360 mm
Part no.: 529603
3D-CAD model - zip
CADENAS PARTcommunity
EPLAN macro - edz
Declaration of Conformity - pdf
Certificate - TÜV Süd - pdf