CS-SMX/FR

Stopping time measurement

Part no.: S991008

Results list: 1 products found
CS40-M-201
Stopping time measurement
Part no.: S981055
  • Description: "Extended"stopping time measurement on a safety-re...
  • Details: Performed if a safety-related sensor safeguards mu...
Part no.: S981055

Delivery to be confirmed
Description "Extended" stopping time measurement on an ESPE unit
Details Performed if an ESPE unit safeguards multiple hazardous movements, e.g., an assembly machine with multiple crushing or shear points that are simultaneously safeguarded by a light curtain.
Conditions It must be possible to stop the machine, support provided by customer's employees and access to the machine for Leuze employees must be ensured.
Restrictions Perform 10 measurements per dangerous movement, evaluate in accordance with ISO 13855:2010, appendix D or in accordance with EN 999.
ECLASS 8.0 40020690
ECLASS 9.0 40020690