Your benefit
- Easy and fast commissioning:Â A wizard integrated in the WebConfig tool guides you quickly and easily through the setup process and simplifies commissioning. For simple applications, the DCR 200i can also be set up for the reading task without a PC using just two buttons on the device
- Codes can be read on various materials:Â Interfering reflections can be reduced thanks to exchangeable polarization filters and diffusor foils
- Detection, even at high object speeds:Â High reading performance and powerful LED illumination enable a good reading result even at high object speeds or partially damaged codes.
- Attractively priced thanks to modular structure:Â Thanks to its modular structure, the DCR 200i can be customized exactly to the requirements of your application in terms of functional scope and performance.
Highlights
Seamless traceability of your products from production to the customer is becoming increasingly important. Whether for allergen management with food products, placement inspections in the pharmaceutical industry, shipping label monitoring in the packaging sector, or testing product quality in the electronics industry – the fast and reliable identification of 1D- and 2D-codes is essential.
The DCR 200i dual code reader combines simple handling with high reading performance – even with demanding reading tasks – and thereby provides support with:
- Identification – ensuring that the label was printed with product, bar code and/or data matrix code
- Track and trace – traceability of ingredients and packed products during production.
Applications
Code reading in the production area
Requirement:
In final assembly, codes are used for the traceability of individual components. These have to be read on a conveyor line, sometimes at high speeds.
Solution:
Thanks to their high scanning rate, the DCR 200i 1D-/2D-code readers enable the reading of codes on quickly moving objects. In addition, optics models are available for various reading ranges.
Code checking in electronics production
Shipping label inspection in conveyor and storage systems
Code inspection on pharmaceutical packages
Label inspection in the food industry
Â
Article list
- Interface: Ethernet, PROFINET, RS 232, RS 422
- Switching principle: MOSFET semiconductor, +24 V switching, MOSFET semi...
- Code types, readable: GS1 Databar Omnidirectional, 2/5 Interleaved, Azte...
- Modulus size, max.: 0.19 ... 0.5 mm
- Interface: Ethernet, PROFINET, RS 232, RS 422
- Switching principle: MOSFET semiconductor, +24 V switching, MOSFET semi...
- Code types, readable: UPC, 2/5 Interleaved, Aztec, Codabar, Code 128, Co...
- Modulus size, max.: 0.35 ... 1 mm
- Interface: Ethernet, RS 232, RS 422, EtherNet IP
- Switching principle: MOSFET semiconductor, +24 V switching, MOSFET semi...
- Code types, readable: EAN 8/13, 2/5 Interleaved, Aztec, Codabar, Code 12...
- Modulus size, max.: 0.35 ... 1 mm
- Interface: Ethernet, RS 232, RS 422
- Switching principle: MOSFET semiconductor, +24 V switching, MOSFET semi...
- Code types, readable: GS1 Databar, 2/5 Interleaved, Aztec, Codabar, Code...
- Modulus size, max.: 0.35 ... 1 mm
- Interface: Ethernet, PROFINET, RS 232, RS 422
- Switching principle: MOSFET semiconductor, +24 V switching, MOSFET semi...
- Code types, readable: Code 32, 2/5 Interleaved, Aztec, Codabar, Code 128...
- Modulus size, max.: 0.5 ... 1 mm
- Interface: Ethernet, RS 232, RS 422
- Switching principle: MOSFET semiconductor, +24 V switching, MOSFET semi...
- Code types, readable: Codabar, 2/5 Interleaved, Aztec, Code 128, Code 32...
- Modulus size, max.: 0.5 ... 1 mm
- Interface: Ethernet, PROFINET, RS 232, RS 422
- Switching principle: MOSFET semiconductor, +24 V switching, MOSFET semi...
- Code types, readable: Code 39, 2/5 Interleaved, Aztec, Codabar, Code 128...
- Modulus size, max.: 0.35 ... 1 mm
- Interface: Ethernet, RS 232, RS 422
- Switching principle: MOSFET semiconductor, +24 V switching, MOSFET semi...
- Code types, readable: GS1 Databar Stacked, 2/5 Interleaved, Aztec, Codab...
- Modulus size, max.: 0.35 ... 1 mm
- Interface: Ethernet, PROFINET, RS 232, RS 422
- Switching principle: MOSFET semiconductor, +24 V switching, MOSFET semi...
- Code types, readable: GS1 Databar Stacked, 2/5 Interleaved, Aztec, Codab...
- Modulus size, max.: 0.35 ... 1 mm
- Interface: Ethernet, RS 232, RS 422, OPC-UA
- Switching principle: MOSFET semiconductor, +24 V switching, MOSFET semi...
- Code types, readable: Pharma Code, 2/5 Interleaved, Aztec, Codabar, Code...
- Modulus size, max.: 0.35 ... 1 mm
- Interface: Ethernet, RS 232, RS 422
- Switching principle: MOSFET semiconductor, +24 V switching, MOSFET semi...
- Code types, readable: Code 128, 2/5 Interleaved, Aztec, Codabar, Code 32...
- Modulus size, max.: 0.35 ... 1 mm
- Interface: Ethernet, RS 232, RS 422, EtherNet IP
- Switching principle: MOSFET semiconductor, +24 V switching, MOSFET semi...
- Code types, readable: EAN 8/13, 2/5 Interleaved, Aztec, Codabar, Code 12...
- Modulus size, max.: 0.35 ... 1 mm