Series | MSI-MC3x |
Functions | Start/restart interlock (RES), Automatic start/restart, Static contactor monitoring (EDM), Stop function according to category Stop 0 |
Restart | Automatic, Manual |
SIL | 3, IEC 61508 |
SILCL | 3, IEC/EN 62061 |
Performance Level (PL) | Up to and including e, EN ISO 13849-1 |
PFHD | 2,5E-08 per hour |
Mission time | 20 years, EN ISO 13849-1 |
Category | Up to and including 4: 1 sensor connected, EN ISO 13849 |
STOP category | 0, IEC/EN 60204-1 |
Protective circuit | Fuse on switching output, upstream |
Input current, max. | 150 mA |
External contact fuse protection per current path | 4 A gG |
Supply voltage UB | 24 V, AC/DC, -10 ... 10 % |
Number of safety-related switching outputs (OSSDs) | 2 Piece(s) |
Number of digital switching outputs | 1 Piece(s) |
Type | Safety-related switching output OSSD |
Voltage type | AC/DC |
Switching element | Relay, NO |
Switching element | Relay, NO |
Type | Digital switching output |
Voltage type | AC/DC |
Switching element | Relay, NC |
Function | EDM switching output |
Response time | 20 ms |
Pickup delay, automatic start | 400 ms |
Pickup delay, manual start | 600 ms |
Time window between 2 channels of a sensor, max. | 500 ms |
Number of connections | 1 Piece(s) |
Function | Voltage supply, Connection to device |
Type of connection | Terminal |
Type of terminal | Screw terminal |
No. of pins | 16 -pin |
Connection cross sections | 1 x 0.2 to 2.5 mm², wire, 1 x 0.2 to 2.5 mm², wire, 1 x 0.25 to 2.5 mm², wire with wire-end sleeve, 2 x 0.2 to 1.0 mm², wire, 2 x 0.2 to 1.5 mm², wire, 2 x 0.25 to 1.0 mm², wire with wire-end sleeve, 2 x 0.5 to 1.5 mm², wire with twin wire-end sleeve |
Dimension (W x H x L) | 22.5 mm x 99 mm x 113.6 mm |
Housing material | Plastic |
Plastic housing | PA |
Net weight | 220 g |
Housing color | Gray |
Type of fastening | Snap-on mounting |
Mechanical life time | 10,000,000 actuation cycles |
Type of display | LED |
Number of LEDs | 3 Piece(s) |
Ambient temperature, operation | 0 ... 55 °C |
Ambient temperature, storage | -25 ... 70 °C |
Relative humidity (non-condensing) | 4 ... 100 % |
Degree of protection | IP 20 (terminals), Installation in switch cabinet or housing with degree of protection of at least IP 54, IP 40 (housing) |
Certifications | TÜV Süd, c UL US |
Test procedure for oscillation in accordance with standard | EN 60947-5-3 |
Customs tariff number | 85423990 |
ECLASS 8.0 | 27371819 |
ECLASS 9.0 | 27371819 |
ECLASS 10.0 | 27371819 |
ECLASS 12.0 | 27371819 |
ETIM 5.0 | EC001449 |
ETIM 6.0 | EC001449 |
ETIM 7.0 | EC001449 |